<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: SNMP Custom Table Sensor

The SNMP Custom Table sensor monitors entries from a table that is provided via the Simple Network Management Protocol (SNMP). You can create one new sensor per table row. For each sensor, you can define up to ten channels. Each channel shows the value of one defined table column.

i_round_blueThe SNMP Library sensor automatically creates SNMP Custom Table sensors when the Management Information Base (MIB) file that you import contains tables.

SNMP Custom Table Sensor

SNMP Custom Table Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: SNMP Aangepaste Tabel
  • French: Table personnalisée (SNMP)
  • German: SNMP (Benutzerdef. Tabelle)
  • Japanese: SNMP カスタムテーブル
  • Portuguese: Tabela (customizada) (SNMP)
  • Russian: Нестандартная таблица SNMP
  • Simplified Chinese: SNMP 自定义表
  • Spanish: Tabla (personalizado) (SNMP)

Remarks

  • This sensor supports IPv6.
  • This sensor has a low performance impact.
  • This sensor can use lookups. Select Lookup as Channel #x Unit and define the lookup file in Channel #x Lookup.
  • It might not work to query data from a probe device via SNMP (querying localhost, 127.0.0.1, or ::1). Add this device with the IP address that it has in your network and create the sensor on this device instead.

Add Sensor

Setting

Description

Table

The sensor shows you the table that the OID returns. Select the table rows that contain the data that you want to monitor. PRTG creates one sensor for each table row that you select.

Basic Sensor Settings

Basic Sensor Settings

Basic Sensor Settings

Setting

Description

Sensor Name

Enter a name to identify the sensor. You can use the placeholders [tablename] and [rowidentifier]. PRTG replaces them with the name of the table and the identifying value of the chosen row respectively. You can select the column that provides the row identifier in the Identification Column option below.

You can also enter a valid OID that is part of a different SNMP table, for example, [1.3.6.1.2.1.2.2.1.2], to query information that the current table does not contain. PRTG adds the same index as in the original table to the OID.

By default, PRTG shows this name in the device tree, as well as in alarms, logs, notifications, reports, maps, libraries, and tickets.

i_round_blueIf the name contains angle brackets (<>), PRTG replaces them with braces ({}) for security reasons. For more information, see the Knowledge Base: What security features does PRTG include?

Parent Tags

The tags that the sensor inherits from its parent device, parent group, and parent probe.

i_round_blueThis setting is for your information only. You cannot change it.

Tags

Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.

i_round_blueIt is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).

i_round_blueFor performance reasons, it can take some minutes until you can filter for new tags that you added.

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • snmpcustomsensor
  • snmpcustomtable

Priority

Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority (i_priority_1) to the highest priority (i_priority_5).

SNMP Table

SNMP Table

SNMP Table

Setting

Description

Table OID

Enter the object identifier (OID) of the SNMP table that you want to monitor. The OID must directly point to an object that represents an SNMP table. PRTG creates one SNMP Custom Table sensor for each table row that you select.

i_round_blueIf you do not enter an OID, you cannot proceed with channel creation.

i_round_blueYou cannot change this value after sensor creation.

Table Specific

Table Specific

Table Specific

Setting

Description

Identifier

This is the value of the column that you selected as the Identification Column during sensor creation. PRTG also displays it in the sensor name to distinguish it from other sensors you created for the same table with other table rows.

Identification Column

Define the identification column for the sensors that you want to create. The sensors use this column to uniquely identify each table row.

i_round_blueWe recommend that you use a unique identification column because it allows the sensors to keep track of changing indexes.

i_round_blueThe value of the column that you select as identification column replaces the [rowidentifier] in the sensor name. This lets you distinguish sensors that you create for the same SNMP table.

i_round_blueAfter sensor creation, this setting shows the table column that you chose as identification column.

Channel #x Name

Enter a name for the channel in which the sensor shows the desired result. Enter a string.

Channel #x Column

Select the table column that, together with the table row, points to the value that you want to monitor in this channel. You can choose between the available columns of the table that you monitor.

Channel #x Value Type

Select the expected numeric type of the results at the OID:

  • Absolute (unsigned integer): Integers without an operational sign, such as 10 or 120.
  • Absolute (signed integer): Integers with an operational sign, such as -12 or 120.
  • Absolute (float): Float values, such as -5.80 or 8.23.
  • Delta (counter): Counter values. PRTG calculates the difference between the last and the current value. PRTG additionally divides the delta value by a time period to indicate a speed value.

i_round_redThis mode only works if the difference between the last and the current value is positive and increases with each scanning interval. This mode does not support negative values and decreasing values.

i_round_redAbsolute (float) and Delta (counter) are not compatible with the unit Lookup.

i_round_blueSee below for other channel settings that you can also change after sensor creation.

i_round_redThis sensor monitors numeric values only. Make sure that you do not select columns that return strings because they lead to the Down status. For example, if you monitor an ifTable, we recommend that you do not select an ifDescr column because this results in an error.

i_round_blueYou cannot change this value after sensor creation.

Channel #x Unit

Define the unit of the data that this sensor receives in this channel:

  • BytesBandwidth
  • BytesMemory
  • BytesDisk
  • Temperature
  • Percent
  • TimeResponse
  • TimeSeconds
  • TimeHours
  • Count
  • CPU
  • BytesFile
  • SpeedDisk
  • SpeedNet
  • Custom
  • Lookup

i_square_cyanFor more information about the available units, see section Custom Sensors.

i_round_blueTo use lookups with this channel, select Lookup and define the lookup file in Channel #x Lookup. Do not use Custom if you use lookups with this sensor.

i_round_redYou cannot use the unit Lookup if you select the value type Delta (counter) or Absolute (float). You are not able to create the sensor in this case.

Channel #x Custom Unit

This setting is only visible if you select Custom above.

Define a unit for the channel value. Enter a string.

Channel #x Lookup

This setting is only visible if you select Lookup above.

Select a lookup file that you want to use with this channel.

Channel #2 - #10

You can define up to 10 channels. You must define at least one channel, so you see all available settings for Channel #1. Specify how to handle all other possible channels:

  • Disable: Do not create this channel.
  • Enable: Create this channel.

i_round_blueIt is not possible to enable or disable channels after sensor creation.

i_round_blueAll channels that you define during the creation of an SNMP Custom Table sensor are the same for all sensors for each table row.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how different channels are shown for this sensor:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you select Stack channels on top of each other above.

Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Scanning Interval

Scanning Interval

Scanning Interval

i_square_cyanFor more information, see section Root Group Settings, section Scanning Interval.

Schedules, Dependencies, and Maintenance Window

i_round_blueYou cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.

Schedules, Dependencies, and Maintenance Window

Schedules, Dependencies, and Maintenance Window

i_square_cyanFor more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.

Access Rights

Access Rights

Access Rights

i_square_cyanFor more information, see section Root Group Settings, section Access Rights.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status

[Value]

The returned numeric values in up to ten channels per table row

More

i_square_blueKNOWLEDGE BASE

How do I find out which OID I need for an SNMP Custom sensor?

What can I monitor with the SNMP Custom Table sensor?

What security features does PRTG include?

My SNMP sensors don’t work. What can I do?

Can I monitor UPS systems complying with the UPS MIB (RFC-1628) with PRTG?